hardware:objectives [2019/12/03 20:40]
Jon Daniels [Table]
hardware:objectives [2019/12/20 23:25]
Jon Daniels [Mechanical Angle]
Line 45: Line 45:
 | Nikon 10x/0.3 W          13°                |  36°              | common low-resolution diSPIM                                     | | Nikon 10x/0.3 W          13°                |  36°              | common low-resolution diSPIM                                     |
 | Olympus 20x/0.5 W        22°                |  45°              | fits better than expected (WD is probably a bit more than spec)  | | Olympus 20x/0.5 W        22°                |  45°              | fits better than expected (WD is probably a bit more than spec)  |
 +| Olympus 20x/1.0 W        49°                |  52°              |   |
 | Nikon 25x/1.1 W          56°                |  58°              | usual lattice detection                                          | | Nikon 25x/1.1 W          56°                |  58°              | usual lattice detection                                          |
 | Olympus 60x/1.1 W        56°                |  57°              | usual oSPIM detection, potential lattice detection               | | Olympus 60x/1.1 W        56°                |  57°              | usual oSPIM detection, potential lattice detection               |
 | SO 54-10-7 29x/0.66 W    30°                |  30°              | usual lattice illumination                                       | | SO 54-10-7 29x/0.66 W    30°                |  30°              | usual lattice illumination                                       |
 | Nikon 20x/1.0 glyc      |  43°                |  ~54°             | cleared tissue confocal used in light sheet (RI 1.44 - 1.50)     | | Nikon 20x/1.0 glyc      |  43°                |  ~54°             | cleared tissue confocal used in light sheet (RI 1.44 - 1.50)     |
 +| Olympus 25x/1.0 glyc    |  43°                |  56°              | cleared tissue confocal used in light sheet (RI 1.41 - 1.52)     |
 | SO 54-10-12 17x/0.4 MI  |  16°                |  20°              | ASI multi-immersion #1 (RI 1.33 - 1.56, nominal 1.45)            | | SO 54-10-12 17x/0.4 MI  |  16°                |  20°              | ASI multi-immersion #1 (RI 1.33 - 1.56, nominal 1.45)            |
 | SO 54-12-8 24x/0.7 MI    29°                |  36°              | ASI multi-immersion #2 (RI 1.33 - 1.56, nominal 1.45)            | | SO 54-12-8 24x/0.7 MI    29°                |  36°              | ASI multi-immersion #2 (RI 1.33 - 1.56, nominal 1.45)            |